Ex 97 AZ

  • Ex zone 1 and 21
  • Thermoplastic enclosure, double insulated
  • Cold-resistant down to -60 °C
  • High degree of protection IP 66 / IP 67 / IP 69
  • Wiring compartment
  • Mounting details to EN 50047
  • With 3 contacts available on request
Notes
  • 1 Ex"e" cable gland M20x1.5 included in delivery
  • The actuator is not included in the delivery of the switches

Technical data

Applied standards EN 60947-5-1, EN 60079-0, EN 60079-1, EN 60079-7, EN 60079-31, EN ISO 13849-1, EN ISO 14119
Enclosure thermoplastic, glass-fibre reinforced, impact resistant, self-extinguishing UL 94 V-0
Cover thermoset, glass-fibre reinforced, impact resistant, self-extinguishing UL 94 V-0
Sealing silicone
Switch type type 2
Coding level low coding
Tightening torque cover screws: 0.4 … 0.45 Nm
connecting thread of cable gland: max. 2 Nm
cap nut of cable gland: max. 5 Nm
Degree of protection IP 66 to EN 60079-0 + IEC/EN 60529 (... -60 °C)
IP 67 to EN 60079-0 + IEC/EN 60529 (... -20 °C)
IP 67 / IP 69 to IEC/EN 60529
IP 69K to ISO 20653
B10d (10 % load) 2 million
TM max. 20 years
Switch insert Type 8080/1 ...
Contact material Silver, nickel-plated
Switching system slow action, positive break NC contacts
Switching elements 1 NC/1 NO contact or 2 NC contacts, type Zb
Connection screw connection terminals
Cable cross-section min. 0,75 mm² / AWG 18, max. 1,5 mm² / AWG 16, incl. conductor ferrules
Cable entry M20 x 1,5; screwing depth max. 9 mm; use only Ex approved and certified cable glands with min. degree of protection IP 66 and suitable for the specified ambient temperature range
Clamping range 7 … 12 mm
Utilisation category AC-15
Rated operating current Ie max. 2 A or 4 A
Rated operating voltage Ue max. 500 VAC, 2Ö: max. 400 VAC
max. 250 VAC for unequal potential
Mechanical life > 1 million operations
Impact energy max. 7 J
Temperature class T6
Ambient temperature –60 °C … +55 °C max. 4 A, +60 °C max. 2 A
Short-circuit protection 2 A / 4 A gG/gN fuse
Ex marking II 2G Ex db eb IIC T6 Gb,
II 2D Ex tb IIIC T80 °C Db
IECEx Ex db eb IIC T6 Gb,
Ex tb IIIC T80 °C Db
Approvals BVS 16 ATEX E 052
IECEx BVS 16.0052

Ordering details

Slow action, 1 NC/1 NO contact

Type   Material no.  
Type    Material no.   
Ex ES 97 AZ-11 -60°C 1360289
Type    Material no.   
Ex ES 97 AZ/90°-11 -60°C 1228646
If you cannot find the version you require, just ask us! Our product portfolio to date has included many customised switchgear variants.

Slow action, 2 NC contacts

Type   Material no.  
Type    Material no.   
Ex ES 97 AZ-02 -60°C 1440509
If you cannot find the version you require, just ask us! Our product portfolio to date has included many customised switchgear variants.

Actuators

Type   Material no.  
Type    Material no.   
Straight actuator AZ 95/97-B1 stock type Standard versions, in stock or available at short notice 1178645
Type   Material no.  
Type    Material no.   
Angled actuator AZ 95/97-B5 stock type Standard versions, in stock or available at short notice 1178646

Accessories

Ex e cable gland M20x1.5 -60 °C
  • For series Ex 97 / Ex 99
  • Explosion protection method Ex „e“ (increased safety)
  • Cold-resistant down to -60 °C