RF RxT SW2.4-safe

Wireless safety foot switches
Material number: RF RxT SW2.4-safe
  • Only available in set with wireless safety foot switch
  • sWave® 2.4GHz wireless technology
  • 2-channel: potential-free, redundant relay outputs
  • 4 change-over contacts, max. 2 A
  • LEDs for indication of switching state
  • SMA plug-in connector for external antenna
  • CANopen diagnostics interface
Contact

Technical data

Applied standards EN 60947-5-1, EN 61000-6-2, EN 61000-6-3, EN 61326-3-1, EN ISO 13849-1, EN 62061, EN 61784-3, EN 60068-2-6, EN 60068-2-27
Degree of protection IP 20 to IEC/EN 60529
Protocol sWave®
Frequency 2.4 - 2.4835 GHz
Transmission power 3.15 mW
Safety-relevant data:
EN ISO 13849-1 Performance Level PL d
Category 3
TM TD_76_14296
MTTFd 74 years
DC/DCavg 60 %
PFHd 1.55 x 10-7 1/h
Connection Antenna: SMA angled plug-in-socket
Rated operating current/voltage Ie/Ue max. 0.1 A/24 VDC -15 % … +10 %;
output contacts: 2 A/24 VDC
Short-circuit protection Ue: 0.5 A (slow blow);
output contacts: 2 A gG/gN fuse
Outputs Relays with change-over contacts, positiveguided
Utilisation category DC-13
EMC rating according to EMC Directive
Degree of pollution 3
Safety class II
Overvoltage category III
Attendance delay tv < 200 ms
Contact resistance 100 mΩ in new condition
Ambient temperature 0 °C … +55 °C
Storage and shipping temperature –25 °C … +85 °C
Mechanical life > 10 million operations
Shock resistance 10 g
Vibration resistance 10 g
Wireless range max. 15 m inside
Wireless approvals Europe: RED 2014/53/EU
USA: FCC-Id. T7V-BC06
Canada: IC 216Q-BC06
Japan: ARIB STD-T66
Approvals TÜV Nord

Accessories

RF CAN Extension Board 4W
  • Extension of RF RxT SW2.4-safe 24 VDC
  • 4 potential-free relay outputs
  • 4 change-over contacts, max. 6 A
  • LEDs for indication of switching state
  • CAN communication
RF SMA antenna socket 0.5 m
  • Suitable for antennae with SMA plug-in connector
  • RF SMA antenna socket with straight SMA plug-in connector
  • Cable length 0.5 m
Power supply 24V DC
  • Stabilised and adjustable output voltage
  • DC OK signalling via LEDs
  • Parallel connection option
  • Push-in terminals
  • Panel installation on mounting rails