Applied standards |
EN 60947-5-2, EN 60079-0, EN 60079-18 |
Enclosure |
thermoset, glass-fibre reinforced, impact resistant, self-extinguishing UL 94 V-0 |
Degree of protection |
IP 67 (EN 60079-0 + IEC/EN 60529) IP 66, IP 68, IP 69 (IEC/EN 60529) IP 69K (ISO 20653) |
Switching system |
reed contacts |
Switching elements |
1 change-over contact |
Connection |
pre-wired cable, Silicone SIHF |
Cable cross-section |
3 x 0.75 mm² |
Cable length |
5 m |
Switching voltage |
max. 250 VAC/DC |
Switching current |
max. 0.5 A DC / max. 0.35 A AC |
Short-circuit current Ik |
max. 2 A |
Switching capacity |
max. 30 W/VA |
Bounce duration |
max. 4.5 ms |
Ambient temperature |
–20 °C … +70 °C |
Mechanical life |
> 1 million operations |
Vibration resistance |
max. 15 g |
Switching distances |
approx. 12 mm (M 100) |
Hysteresis |
approx. 6 mm (M 100) |
Impact energy |
max. 7 J |
Ex marking |
II 2G Ex mb IIC T6 Gb,
II 2D Ex mb IIIC T80 °C Db IECEx Ex mb IIC T6 Gb Ex mb IIIC T80 °C Db |
Approvals |
DMT 01 ATEX E 058 X IECEx BVS 07.0007 X |
Weight |
752 g |