RF RC M30
Wireless magnetic sensor
- Thermoplastic or stainless steel enclosure
- Power supply: Lithium battery
- sWave® wireless technology
Applied standards | EN 60947-5-1, EN 60079-0, EN 60079-1, EN 60079-31, EN ISO 13850, EN ISO 13849-1 |
---|---|
Enclosure | thermoset, UV resistant to EN ISO 4892 |
Cover | thermoset, UV resistant to EN ISO 4892 |
Degree of protection | IP 65 to IEC/EN 60529 |
B10d (10 % load) | 200 000 |
TM | max. 20 years |
Switch insert | 2 x Ex 14 |
Contact material | silver |
Switching system | slow action, positive break NC contacts ![]() |
Switching elements | 2 NC/2 NO contacts, type Zb |
Connection | pre-wired cable H05VV-F |
Cable length | 3 m |
Rated impulse withstand voltage Uimp | 4 kV |
Rated insulation voltage Ui | 250 V |
Conventional thermal current Ithe | T6: 6 A, T5: 3 A |
Utilisation category | AC-15; DC-13 |
Rated operating current/voltage Ie/Ue | 6 A/250 VAC; 0.25 A/230 VDC |
Short-circuit protection | 6 A gG/gN fuse |
Ambient temperature | T6: –20 °C … +65 °C, T5: –20 °C … +75 °C, +90 °C with max. 3 A |
Mechanical life | > 100 000 operations |
Max. wire length | 2 x 50 m |
Impact energy | max. 7 J |
Ex marking | ![]() ![]() T80 °C/T95 °C Db IECEx Ex db IIC T6/T5 Gb, Ex tb IIIC T80 °C/T95 °C Db |
Approvals | PTB 03 ATEX 1070 X * IECEx PTB 06.0098X * * referring to the switch insert ![]() |