RF RC M30
Wireless magnetic sensor
- Thermoplastic or stainless steel enclosure
- Power supply: Lithium battery
- sWave® wireless technology
Applied standards | EN 60947-5-1, EN 60947-5-5, EN 60079-0, EN 60079-1, EN 60079-31, EN ISO 13850, EN ISO 13849-1 |
---|---|
Enclosure | aluminium die-cast, enamel finish |
Cover | thermoplastic, glass-fibre reinforced, impact resistant, self-extinguishing UL 94 V-0 |
Degree of protection | IP 65 (EN 60079-0 + IEC/EN 60529) IP 67 (IEC/EN 60529) |
B10d (10 % load) | 200 000 |
TM | max. 20 years |
Switch insert | 1 x Ex 14 |
Contact material | silver |
Switching system | slow action, positive break NC contacts ![]() |
Switching elements | 1 NC/1 NO contact or 2 NC contacts, type Zb |
Connection | pre-wired cable H05VV-F |
Cable cross-section | 4 x 0.75 mm² (incl. conductor ferrules) |
Cable length | 3 m |
Rated impulse withstand voltage Uimp | 4 kV |
Rated insulation voltage Ui | 250 V |
Conventional thermal current Ithe | T6: 6 A, T5: 3 A |
Utilisation category | AC-15; DC-13 |
Rated operating current/voltage Ie/Ue | 6 A/250 VAC; 0.25 A/230 VDC |
Short-circuit protection | 6 A gG/gN fuse |
Ambient temperature | T6: –20 °C … +65 °C, T5: –20 °C … +75 °C, +90 °C with max. 3 A |
Mechanical life | > 100 000 operations |
Max. wire length | 100 m |
Impact energy | max. 7 J |
Ex marking | ![]() ![]() T80 °C/T95 °C Db IECEx Ex d IIC T6/T5 Gb, Ex tb IIIC T80 °C/T95 °C Db |
Approvals | PTB 11 ATEX 1003 X IECEx PTB 07.0034 X Japan: TIIS TC22472X (Ex 14) ![]() ![]() ![]() ![]() |
Slow action, 1 NC/1 NO contact
Ex ZS 80 1Ö/1S WVD - 3m | 1181373 | ||
Ex ZS 80 1NC/1NO WVD - 3m JPEx | 1456123 | ||