RF RC M30
Wireless magnetic sensor
- Thermoplastic or stainless steel enclosure
- Power supply: Lithium battery
- sWave® wireless technology
Applied standards | EN 60947-5-1, EN 60079-0, EN 60079-1, EN 60079-31 |
---|---|
Enclosure | aluminium die-cast, hard-coated, powder-coated, anthracite grey, similar to RAL 7016 |
Cover | stainless steel 1.4404, powder-coated, signal yellow, similar to RAL 1003 |
Degree of protection | IP 66/67 to IEC/EN 60529 |
B10d (10 % load) | 2 million |
TM | max. 20 years |
Contact material | silver, gold-plated |
Switching elements | 1 NC/1 NO contact, type Zb |
Switching system | slow action |
Connection | cable BETAflam 145 flex |
Cable cross-section | 4 x 0.75 mm² (incl. conductor ferrules) |
Rated impulse withstand voltage Uimp | 4 kV |
Rated insulation voltage Ui | 250 V |
Conventional thermal current Ithe | T6: 6 A, T5: 3 A |
Utilisation category | AC-15; DC-13 |
Rated operating current/voltage Ie/Ue | 6 A/250 VAC; 0.25 A/230 VDC |
Short-circuit protection | 6 A gG/gN fuse |
Ambient temperature | T6: –40 °C ... +65 °C, T5: –40 °C ... +75 °C, +90 °C with max. 3 A |
Mechanical life | > 1 million operations |
Impact energy | max. 7 J |
Ex marking | ![]() ![]() T80 °C/T95 °C Db IECEx Ex d IIC T6/T5 Gb, Ex tb IIIC T80 °C/T95 °C Db |
Approvals | PTB 11 ATEX 1003 X IECEx PTB 07.0034 X |