Foot switch with thermoplastic enclosure

KF 2


  • 2-pedal type

  • Thermoplastic enclosure

  • Small flat design

  • Max. 2 contacts per pedal

  • With wiring compartment or pre-wired cable, cable length 2 m

  • Reed contacts for low currents from 1 mA to 1 A

  • Micro switches for current load up to 5 A

  • Version "D": with pressure point

  • Version "HS": with Hall sensor

  • Version "HID": with USB HID-Interface

Technical data

Applied standards

EN 60947-5-1

Enclosure

thermoplastic, glass-fibre reinforced, impact resistant, self-extinguishing UL 94 V-0

Pedal

thermoplastic, glass-fibre reinforced, impact resistant, self-extinguishing UL 94 V-0

Degree of protection

IP65 (IEC/EN 60529)

Connection

wiring compartment with cable gland M12 x 1.5 or prewired cable, length 2 m

Switching system

reed contacts or snap action: micro switch

Switching voltage

12 … 250 VAC/DC

Switch-on current

reed contacts: max. 1 A, micro switch: max. 5 A

Switch-on power

reed contacts: max. 30 VA, micro switch: max. 1250 VA

Ambient temperature

–10 °C … +60 °C

Mechanical life

> 1 million operations

Approvals

d *
] *