Safety sensor

BZ 16 IP69 Extreme


  • Version with higher degree of protection IP69: suitable for cleaning with 80 °C hot water at 100 bar pressure at a distance of 100 mm from different directions

  • Thermoplastic enclosure

  • Suitable for the food processing industry

  • Long life

  • Differential inputs: Induction / magnetic operating principle

  • Internal monitoring, high manipulation protection

  • Potential-free outputs

  • Signalling contact

  • Status LED

  • 1 NO/2 NC contact or 3 NC contacts

  • Available with 2 different actuating planes:
    actuating from the top "T",
    actuating from the front "F".
    Please indicate the desired actuating plane when ordering.

  • Rated switching distance sn = 12 mm

  • Wiring compartment

Notes
  • 1 cable gland M20x1.5 - IP69 and 2 locking screws M20x1.5 included in delivery

  • The actuator is not included in the delivery of the switches

Technical data

Applied standards

EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 60947-5-2, EN 60947-5-3, EN ISO 14119, EN 60204-1, EN ISO 13849-1, EN 62061, 2004/108/EG

Enclosure

thermoplastic, glass-fibre reinforced, shockproof, self-extinguishing UL 94 V-0

Defined object

actuator BZ 16-B1 with low coding

Sensor type

type 4 interlocking device

Coding level

low coding

Tightening torque

enclosure mounting screws: max. 2 Nm
cover screws: max. 1.5 Nm
actuator screws: max. 2 Nm

Degree of protection

IP69 (IEC/EN 60529)

Rated switching distance sn

12 mm (10 mm with flush mounting)

Assured switching distance »ON« sao 

10 mm (8 mm with flush mounting)

Assured switching distance »OFF« sar 

25 mm

Hysteresis

approx. 6 mm

Sideways tolerance

≤ 3 mm

Repeatability

± 1 mm

Rated operating current/voltage Ie/Ue

140 mA/24 VDC ± 15 %
(reverse voltage protected);
output contacts: max. 3 A/24 VAC/DC, min. 10 mA/5 VAC/DC;
signalling contact: max. 1 A/24 VAC/DC, min. 100 μA/100 mVDC

No-load supply current I0

≤ 70 mA

Short-circuit protection

Ue: 0.25 A (slow blow);
output contacts: 4 A (gG/gN) incoming series-connected

Outputs

2 enabling paths (2 NC or 1 NO/1 NC)
1 signalling contact (1 NC)

Switching voltage

max. 30 VAC/DC

Conditional short-circuit current

100 A

Utilisation category

AC-15; DC-13 (output contacts)
AC-12; DC-12 (signalling contact)

Rated insulation voltage Ui

250 VAC

Rated impulse withstand voltage Uimp

1.5 kV

Voltage drop at Ie

max. 0.6 V

Overvoltage category

III

Switching frequency

max. 1 Hz

Attendance delay tv

< 300 ms

Risk time

max. 165 ms

Degree of pollution

3

Ambient temperature

0 °C … +55 °C

Storage and shipping temperature

–20 °C … +70 °C

Mechanical life

50 mio. operations

Contact material

output contacts: AgSnO self-cleaning, positive-guided; signalling contact: AgNi, gold-plated

Contact resistance

output contacts: 100 mΩ in new condition; signalling contact: max. 30 mΩ

Connection

wiring compartment with socket screw clamps 8-pole

Cable entry

3 x M20 x 1.5 (press-out blanks in enclosure)

Cable cross-section

min. 0.14 mm² (AWG 28), max. 1.5 mm² (AWG 16)

EN ISO 13849-1

Performance Level PL e

Category

3

B10d (10 % load)

20 million

TM

max. 20 years

MTTFd

100 years

DC/DCavg

96 %

EN 62061

SIL CL 3

PFHd

≥ 4.29 x 10-8 1/h

hop

8 h/day

dop

220 days/year

tzyklus

20 s

Note

The safety-related data are based on a load of 24 V / 0.1 A / DC-1 for the enabling paths. With higher load currents for the enabling paths and other requirement rates nop, the safety-related data vary from the given data and can be provided on request.
 

Downloads

Loading...
Mounting and wiring instructions – BZ 16 Extreme

German, English, French, Italian, Portuguese, Russian

PDF 2 MB 19.09.2023
Please go to the relevant product pages for additional downloads.
Loading...