Ex RC Si M30 1Ö/1S LED-3G/D - 1m

Ex safety sensor
Material number: 1180481
  • Ex zone 2 and 22
  • Metal enclosure
  • Reed contacts, coded
  • Actuation from front
  • Switching distance up to 10 mm
Contact

Technical data

Applied standards EN 60947-5-1, EN 60947-5-3, EN 60079-0, EN 60079-18, EN ISO 13849-1, EN ISO 14119
Enclosure brass, nickeled
Sensor type type 4 interlocking device
Tightening torque mounting nut: max. 75 Nm
Degree of protection IP 67 to IEC/EN 60529
Safety-relevant data:
EN ISO 13849-1 Performance Level PL e
Category 4
B10d (10 % load) 20 million
TM max. 20 years
MTTFd > 100 years
DC/DCavg > 99 %
hop 8 h/day
dop 220 days/year
tzyklus 20 s
Note The safety-related data are only valid in combination with a safety module, e.g. SRM 21 RT2 (mat. no. 1179203).
 
Switching system reed contacts
Switching elements 1 NC/1 NO contact
Connection cable H05VV5-F 5G
Cable cross-section 5 x 0.5 mm²
Cable length 1 m
Switching voltage max. 30 VDC
Rated operating current/voltage Ie/Ue max. 20 mA / 24 VDC
Switching capacity max. 0.6 W
Voltage drop at Ie max. 3 V
Operation cycles max. 1600/h
Rated switching distance sn 10 mm
Assured switching distance »ON« sao  8 mm
Assured switching distance »OFF« sar  30 mm
Repeatability ± 0.5 mm
Hysteresis approx. 14 mm
Temperature class T6
Ambient temperature –20 °C … +65 °C
Mechanical life > 10 million operations
Impact energy max. 7 J
Ex marking II 3G Ex mc IIC T6 Gc X,
II 3D Ex mc IIIC T80°C Dc

Contact diagram

Axial misalignment


Actuators

Type   Material no.  
Type    Material no.   
Actuating magnet coded Ex MC 30 stock type Standard versions, in stock or available at short notice 1180333
Type    Material no.   
Actuating magnet coded Ex MC 30 Niro stock type Standard versions, in stock or available at short notice 1181818

Accessories

Safety relay module SRM 21 RT2
  • Enclosure width: 22.5 mm
  • 2 NC or 1 NC/1 NO contact can be connected
  • Feedback circuit
  • 2 enabling paths
  • 1 transistor output
  • Manual or automatic reset
  • LED indicator for switching condition
  • Crossed wire monitoring