Ex emergency pull-wire switch

Ex ZS 92 S


  • Ex zone 1 and 21

  • Corrosion-resistant aluminium enclosure

  • Screws made of stainless steel

  • Wire length up to 2 x 100 m

  • Release by lever

  • F = Reset lever at the front side

  • Back and base mounting possible

  • Wire pull and breakage detection

Technical data

Applied standards

EN 60947-5-1, EN 60947-5-5, EN ISO 13850, EN ISO 13849-1, EN IEC 60079-0, EN 60079-1, EN IEC 60079-7, EN 60079-31, EN 620-5.7.2.9, AS 1755-2000-2.7.9.1, AS/NZS 4024.3610:2015-2.10.6.2

Enclosure

aluminium die-cast, corrosion-resistant, powder-coated, passivated, shockproof, anthracite grey, similar to RAL 7016

Cover

aluminium die-cast, corrosion-resistant, powder-coated, passivated, shockproof, signal yellow, similar to RAL 1003

Actuating lever

aluminium die-cast, corrosion-resistant, powder-coated, passivated, shockproof, signal red, similar to RAL 3001

Reset lever

aluminium die-cast, corrosion-resistant, powder-coated, passivated, shockproof, sky blue, similar to RAL 5015

Screws

stainless steel

Tightening torque

cover screws: max. 2.5 Nm
actuator screws: max. 6 Nm

Degree of protection

-10°C: IP65 (EN 60079-0 + IEC/EN 60529)
-20°C/-30°C: IP66 (EN 60079-0 + IEC/EN 60529)

B10d (10 % load)

100 000

TM

max. 20 years

Contact material

silver

Switching system

snap action, positive break NC contacts A

Switching elements

2 NC/2 NO contacts, type Zb

Connection

screw connection terminals

Cable cross-section

min. 0.75 mm² (AWG 18), max. 2.5 mm² (AWG 14), incl. conductor ferrules

Cable entry

2 x M25 x 1.5

Rated impulse withstand voltage Uimp

6 kV

Rated insulation voltage Ui

250 V

Conventional thermal current Ithe

2 A / 4 A / 6 A

Utilisation category

AC-15

Rated operating current/voltage Ie/Ue

max. 2 A/4 A/6 A / 250 VAC

Short-circuit protection

2 A / 4 A / 6 A gG/gN fuse

Mechanical life

> 50 000 operations

Max. wire length

2 x 100 m

Ambient temperature

–10 °C … +55 °C, –20 °C … +55 °C or –30 °C … +65 °C (depending on the variant)

Degree of pollution

3

Actuating force

actuating lever approx. 30 N; reset lever approx. 40 N

Ex marking

L II 2G Ex db eb IIC T6 Gb,
L II 2D Ex tb IIIC T80 °C Db
IECEx Ex db eb IIC T6 Gb,
Ex tb IIIC T80 °C Db

Approvals

BVS 19 ATEX E 076
IECEx BVS 19.0074
f d a

Downloads

Loading...
Mounting and wiring instructions – Ex ZS 92 S

German, English, French, Italian, Portuguese, Russian

PDF 5 MB 04.10.2023
Please go to the relevant product pages for additional downloads.

Variants / Options

The following variants / options are available on request:

  • Cold-resistant version down to -30 °C
to your contact persons
Loading...

Other interesting products

Special version only for dust Ex zone 22

Ex Safety