RF RC M30
Wireless magnetic sensor
- Thermoplastic or stainless steel enclosure
- Power supply: Lithium battery
- sWave® wireless technology
Applied standards | EN ISO 13849-1, EN 62061, EN 60204-1, BG-GS-ET-20, EN 60947-5-1, EN 60947-5-3, EN 61326-3-1 |
---|---|
Enclosure | polycarbonate, black |
Tightening torque | screw connection terminals: approx. 0.8 Nm |
Degree of protection | enclosure IP 40, terminal block IP 20 to IEC/EN 60529, protection against contact to VBG 4 |
Safety-relevant data: | |
EN ISO 13849-1 | Performance Level PL e |
Category | 4 |
TM | max. 20 years |
MTTFd | > 113 years |
DC/DCavg | > 99 % |
EN 62061 | SIL CL 3 |
PFHd | 3 x 10-8 1/h |
hop | 8 h/day |
dop | 220 days/year |
tzyklus | 30 s |
EN 60204-1 | stop category 0 |
Note | The safety-related data are based on a load of 24 V / 1 A / DC-1 for the enabling paths. With higher load currents for the enabling paths and other requirement rates nop, the safety-related data vary from the given data and can be provided on request. |
Contact material | Silver, gold flashed |
Mounting | DIN rail mounting |
Connection | screw connection terminals with + and - screws |
Cable cross-section | min. 1x 0.5 mm² (AWG 20) including conductor ferrules, max. 1x 2.5 mm² (AWG 14) including conductor ferrules, 2x 1.5 mm² (AWG 16) including conductor ferrules |
Rated operating voltage Ue | 24 VDC ±15 % |
Rated operating current Ie | 0.125 A |
Rated insulation voltage Ui | 250 VAC |
Rated impulse withstand voltage Uimp | 4 kV |
Conditional short-circuit current | 100 A |
Inputs | 1 NC/1 NO contact or 2 NC contacts, 1 feedback circuit, 1 start input (monitored) |
Outputs | 2 enabling paths, 1 transistor output as signalling output |
Rated operating current/voltage Ie/Ue | to EN 60947-5-1: 2 A/230 VAC; 1 A/24 VDC to CSA: B300/R300, 250 VAC |
Conventional thermal current Ithe | 5 A |
Utilisation category | AC-15; DC-13 |
Contact load capacity | min. 10 mA |
Typ. input voltage | 20 VDC |
Typ. input current | 22 mA |
Max. load of signalling output | 20 mA |
Short-circuit protection | power supply 2A slow blow, enabling paths 6 A gG/gN fuse |
Pick-up delay | ≤ 20 ms |
Drop-out delay | ≤ 20 ms |
Risk time | ≤ 0.5 s (switch-on delay) |
Attendance delay tv | < 200 ms |
Mechanical life | > 50 million operations |
Display | 1 LED for supply voltage, 1 LED each for input A and B, 1 LED for authorisation |
Degree of pollution | 2 |
Overvoltage category | III |
Ambient temperature | –22 °C … +55 °C |
Storage and shipping temperature | –22 °C … +70 °C |
Relative humidity | 10 % ... 90 % |
Shock resistance | 15 g |
Approvals | ![]() ![]() |
Note | Inductive loads (contactors, relays etc.) are to be suppressed by suitable circuitry. |
Safety relay module SRM 21 RT2 | stock type Standard versions, in stock or available at short notice | 1179203 | |