Ex 95
Features/Options
- Ex zone 1 and 21
- Thermoplastic enclosure
- Design according to DIN EN 50 047
- Wiring compartment
- Double insulation

- Available with overlapping contacts
- Actuator heads can be repositioned by 4 x 90°
- Angle of offset roller lever can be adjusted in 10° steps
- With gold-plated contacts available on request
- Special version with NIRO screws and NIRO 1.4571 plunger, degree of protection IP 66, salt-mist proof, available
- Special version only for dust Ex zone 22 available
- N.B.: Please state required approvals for Russia and China with your order!
Product image

Technical data
| Standards | EN 60947-5-1; EN 1088; EN 60079-0, EN 60079-1, EN 60079-7; EN 61241-0, EN 61241-1 |
|---|---|
| Design | DIN EN 50 047 |
| Enclosure | glass-fibre reinforced, shock-proof thermoplastic, self-extinguishing UL 94-V0 |
| Switch insert | Ex 95 |
| Degree of protection | IP 67 or IP 66, salt-mist proof to IEC/EN 60529 |
| Contact material | silver |
| Switching system | slow action, positive break NC contact ![]() |
| Switching elements | change-over contact with double break Zb or 2 NC contacts, galvanically separated contact bridges |
| Connection | M3 screw clamps |
| Cable section | max. 1.5 mm2 (incl. conductor ferrules) |
| Uimp | 4 kV |
| Ui | 250 V |
| Ithe | 6 A |
| Ie/Ue | 6 A/250 VAC; 0.25 A/230 VDC |
| Utilisation category | AC-15, DC-13 |
| Max. fuse rating | 6 A gL/gG D-fuse |
| Ambient temperature | –20 °C … +60 °C |
| Mechanical life | > 1 million operations |
| Switching frequency | 3600/h |
| Repeat accuracy | ±0.1 mm |
| Contact gap | max. 2 x 3.5 mm |
| Ex marking | II 2G Ex de IIC T6, II 2D Ex td A21 IP67 T80°C |
| Approvals | DMT 01 ATEX E118; IECEx in 2011 ![]() |






II 2G Ex de IIC T6,