ES 14

Features/Options

  • Thermoplastic enclosure
  • Double insulated Schutzisoliert
  • Slow action Zwangsöffnung, change-over contact or 2 NC contacts with double break
  • Overlapping contacts available
  • Mounting hole diameter 22.5 mm
  • Mounting details to DIN EN 50 047
  • With pre-wired cable, cable length 1 meter (other cable lengths available on request)
  • With gold-plated contacts available on request
  • With connector M12 x 1, 4-pole available on request
  • Version with cable on side available on request
  • Ex-version available

Product image

 

Technical data

Standards EN ISO 13849-1; IEC/EN 60947-5-1
Enclosure glass-fibre reinforced, shock-proof thermoplastic, self-extinguishing UL 94-V0
Degree of protection IP 65/67 to IEC/EN 60529
Contact material silber
Switching system slow action, positive break NC contacts Zwangsöffnung
Switching elements change-over contact with double break or 2 NC contacts, galvanically separated contact bridges
Connection cable H05VV-F
Cable section 4 x 0.75 mm²
Uimp 4 kV
Ui 250 V
Ithe 6 A
Ie/Ue 6 A/250 VAC; 0,25 A/230 VDC
Utilisation category AC-15, DC-13
Max. fuse rating 6 A gL/gG D-fuse
Ambient temperature –20 °C … +75 °C
Mechanical life > 1 million operations
Switching frequency 1800/h
Contact opening 2 x 4 mm
Approvals