ZS 73 S
Features/Options
- Metal enclosure
- 2 or 3 contacts
- Wire length up to 2 x 100 m
- Release by push button (VD) or key (VS) possible
- Available without unlocking mechanism (per DIN EN 60947-5-1)
- Wire pull and breakage detection
- Indicator lamps for various voltages are indicated in chapter accessories in the appendix
- Indicator lamp position in the left side cable entry, other positions possible on request
- With 2 cable entries available on request
- Ex version available
- Niro version available with pull-wire lever and screws made of stainless steel 1.4305 and hard-coated enclosure with enamel finish - see chapter/ ZS 73 S Niro hard-coated Extreme >
Product image

Technical data
| Standards | EN ISO 13849-1; IEC/EN 60947-5-1; IEC/EN 60947-5-5; EN 418 |
|---|---|
| Enclosure | aluminium die-cast, enamel finish |
| Cover | glass-fibre reinforced, shock-proof thermoplastic, ultramid |
| Degree of protection | ZS 73 S VD: IP 65; ZS 73 S VS: IP 54 to IEC/EN 60529 |
| Contact material | silver |
| Switching elements | change-over contact with double break or 2 NC contacts or 2 NC/1 NO contact |
| Switching system | snap action, positive break NC contacts ![]() |
| Connection | screw terminals |
| Cable section | max. 2.5 mm2 (incl. conductor ferrules) |
| Cable entry | 2 x M20 x 1.5 |
| B10d (10% Load) | 200.000 |
| TM | max. 20 years |
| Uimp | 2 contacts: 6 kV, 3 contacts: 1 kV |
| Ui | 2 contacts: 400 V, 3 contacts: 250 V |
| Ithe | 2 contacts: 6 A, 3 contacts: 2 A |
| Utilisation category | AC-15 |
| Ie/Ue | 2 contacts: 6 A/400 VAC, 3 contacts: 2 A/250 VAC |
| Max. fuse rating | 2 contacts: 6 A gL/gG D-fuse, 3 contacts: 2 A gL/gG D-fuse |
| Ambient temperature | –25 °C … +70 ºC |
| Mech. life | > 100.000 operations |
| Indicator lamp | as option |
| Max. wire length | 2 x 100 m |
| Features | wire pull and breakage detection |
| Approvals | ![]() |