Safety relay module SRM 21 RT2

Features/Options

  • Enclosure width: 22.5 mm
  • Input: 2 NC or 1 NC/1 NO contact
    can be connected
  • Feedback circuit
  • 2 enabling paths
  • 1 transistor output
  • Manual or automatic reset
  • Switching position indication by LED
  • Crossed wire monitoring

Product image

 

Technical data

Standards IEC/EN 60204-1,
IEC/EN 60947-5-1,
IEC/EN 60947-5-3/PDF-M, EN 954-1, BG-GS-ET 20
GS-ET 14
Enclosure black polycarbonate; polyamide terminal clamps, top hat section rail mounting to EN 50022
Connection screw terminals with + and - screws
Cable section 1x 2.5 mm²/2x 1.5 mm² strand including conductor ferrules,
1x 4 mm²/
2x 2.5 mm² massive
Degree of protection Enclosure IP 40, Terminal block
IP 20 to IEC/EN 60529,
shock protection to VBG 4

Safety-relevant data:
EN 954-1 Category 4
EN ISO 13849-1 PL e
MTTFd 39.5 years
DIN EN 62061 SIL CL 3
PFHD ≥ 3 x 10-8
TM max. 20 years

Ie/Ue power supply

0.1 A/24 VDC ±15 %
Inputs 1 NC/1 NO contact or 2 NC contacts
1 feedback input, 1 reset input
Outputs enabling paths: positive-guided contacts, 1 transistor output as signalling contact
Utilisation category AC-15; DC-13
Ie/Ue enabling paths 3 A/230 VAC; 2 A/24 VDC
Max. output current transistor
output Ia
20 mA
Max. fuse rating Ue 2 A gL/gG D-fuse
Max. fuse rating enabling paths 6 A gL/gG D-fuse
Classification stop category 0
Dropout delay < 20 ms
Risk time < 200 ms
Mechanical life > 50 million operations
LED indications 4: operation, authorisation, inputs A and B
Degree of pollution 3 to DIN VDE 0110
Overvoltage category III
Ambient temperature 0 °C … +55 °C
Approvals BRD