Position switch

HS 98 Extreme with analogue output


  • With analogue output

  • Design to EN 50041

  • Wiring compartment

  • High degree of protection IP66 / IP67

  • Various output values available:
    0 … 10 VDC, 0 … 20 mA or 4 … 20 mA

Technical data

Applied standards

EN 60947-5-2, EN 60947-5-7

Enclosure

aluminium die-cast, corrosion-resistant, powder-coated, anthracite grey, similar to RAL 7016

Cover

stainless steel 1.4401, powder-coated, signal yellow, similar to RAL 1003

Degree of protection

IP66/IP67 (IEC/EN 60529)

Switching system

Hall sensor with analogue output

Linearity

2 %

Connection

Cage clamps

Cable cross-section

max. 0.08 … 2.5 mm², AWG 28 … 12

Cable entry

1 x M20 x 1.5

Over temperature protection

monitoring via μ controller + NTC

Rated operating voltage Ue

24 VDC

Rated operating voltage range UB

18 … 30 VDC

Rated output current

Q2: ≤ 100 mA short-circuit protected

Voltage drop at Ie

2 V

Attendance delay tv

< 500 ms

Short-circuit protection

internal fuse 0.375 A F

Ambient temperature

–20 °C … +60 °C

Mechanical life

> 1 million operations

Downloads

Loading...
Mounting and wiring instructions – HS 98 Extreme

German, English, French, Italian, Portuguese, Russian

PDF 302 KB 25.09.2023
Please go to the relevant product pages for additional downloads.

Variants / Options

The following variants / options are available on request:

  • Further actuators
to your contact persons