Ex 95 T5C
Features/Options
- Ex zone 1 and 21
- Double insulated

- Slow action
, change-over contact with double break - Cable entry M20 x 1.5
- Wiring compartment
- With gold-plated contacts available on request
- Mounting details to
DIN EN 50 047 - Actuator head can be repositioned in
4 x 90° steps - Special version only for dust Ex zone 22 available
- N.B.: Please state required approvals for Russia and China with your order!
Product image

Technical data
| Standards | EN 60947-5-1; EN 1088; EN 60079-0, EN 60079-1, EN 60079-7; EN 61241-0, EN 61241-1; EN ISO 13849-1 |
|---|---|
| Design | mounting details to |
| Enclosure | glass-fibre reinforced, shock-proof thermoplastic, self-extinguishing |
| Degree of protection | IP 67 to IEC/EN 60529 |
| Contact material | silver |
| Switching system | slow action, positive break NC contacts ![]() |
| Switching elements | change-over contact with double break Zb or 2 NC contacts, galvanically separated contact bridges |
| Connection | M3 screw clamps |
| Cable section | max. 1.5 mm2 (incl. conductor ferrules) |
| Cable entry | M20 x 1.5 |
| B10d (10% Load) | 2 million |
| TM | max. 20 years |
| Uimp | 4 kV |
| Ui | 250 V |
| Ithe | 6 A |
| Ie/Ue | 6 A/250 VAC; 0.25 A/230 VDC |
| Utilisation category | AC-15, DC-13 |
| Max. fuse rating | 6 A gL/gG D-fuse |
| Ambient temperature | –20 °C … +60°C |
| Mechanical life | > 1 million operations |
| Ex marking | II 2G Ex de IIC T6,II 2D Ex tD A21 IP67 T80°C |
| Approvals | DMT 01 ATEX E 118; IECEx in 2011 ![]() |





II 2G Ex de IIC T6,