Ex 13
Features/Options
- Ex zone 1 and 21
- Thermoplastic enclosure
- Double insulation

- Slow action
, change-over contact with double break - Slow action with overlapping contacts available
- Suitable for in-line mounting
- With pre-wired cable
- Special cables available on request
- Gold-plated contacts available on request
- Special version only for dust Ex zone 22 available
- N.B.: Please state required approvals for Russia, China, Brazil and North America with your order!
Product image

Technical data
| Standards | EN 60947-5-1; EN 1088; EN 60079-0, EN 60079-1, EN 60079-31 |
|---|---|
| Enclosure | glass-fibre reinforced, shock-proof thermoplastic, self-extinguishing UL 94-V0 |
| Degree of protection | IP 65 to IEC/EN 60529 |
| Contact material | silver |
| Switching system | slow action, positive break NC contact ![]() |
| Switching elements | change-over contact with double break Zb, galvanically separated contact bridges |
| Connection | cable H05VV-F, 4 x 0.75 mm2 |
| Uimp | 4 kV |
| Ui | 250 V |
| Ithe | T6: 6 A; T5: 3 A |
| Ie/Ue | 6 A/250 VAC; 0.25 A/230 VDC |
| Utilisation category | AC-15, DC-13 |
| Max. fuse rating | 6 A gG/gN-fuse |
| Ambient temperature | T6: –20°C … +65ºC; T5: –20°C … +95ºC |
| Mechanical life | > 1 million operations |
| Switching frequency | 1800/h |
| Repeat accuracy | ±0.1 mm |
| Contact gap | max. 2 x 4 mm |
| Ex marking | II 2G Ex d IIC T6/T5 Gb, II 2D Ex tb IIIC T80°C/T95°C Db IP65 IECEx Ex d IIC T6/T5 Gb, Ex tb IIIC T80°C/T95°C Db IP65 |
| Approvals | PTB 03 ATEX 1068 X IECEx PTB 06.0053 X ![]() |





II 2G Ex d IIC T6/T5 Gb,