// EXPLOSION PROTECTION

EEx 12

Technical data

Standards IEC/EN 60947-5-1
Enclosure GD-AL alloy
Protection class IP 65 according to IEC/EN 60529
Contact material silver
Switching elements change-over contact with single break
Switching system snap action
Connection cable H05VV-F
Cable section 4 x 0.75 mm2
Uimp 4 kV
Ui 250 V
Ithe 5 A
Utilisation category AC-15; DC-13
Ie/Ue 5 A/250 VAC; 0,16 A/230 VDC
Max. fuse rating 5 A gL/gG D-fuse
Mechanical life > 1 million operations
Switching frequency 1800/h
Ambient temperature –20 °C … +60 ºC, +75°C bei T5
Mechanical life > 1 Million Schaltspiele
Switching frequency 1800/h
Repeat accuracy ± 0,1 mm
Contact gap -
Ex certification EEx geprüft II 2G EEx d IIC T6,
II 2D IP65 T80°C
Approvals PTB 03 ATEX 1067 X

Features/Options

  • With gold-plated contacts available on request
  • Available with hard-coated enclosure for use in aggressive conditions

Cable on side

Mounting thread M16 x 1.5

Mounting thread on side
M16 x 1.5