// EXPLOSION PROTECTION

EEx 95 AZ

Technical data

Standards IEC/EN 60947-5-1; EN 1088;
EN 50014; EN 50018; EN 50019;
EN 50281-1-1
Enclosure glass-fibre reinforced, shock-resistant thermoplastic, auto-extinguishing UL 94-V0
Actuator stainless steel 1.4301
Switch insert -
Protection class IP 67 to EN 60529
Contact material silver
Switching system slow action, NC contact with positive break Zwangsöffnung
Switching elements changeover contact Zb or 2 NC contacts, galvanically separated contact bridges
Anschlussart M3 Schraubklemmen
Cable section max. 1.5 mm 2 (incl. conductor ferrules)
Cable length -
Uimp 4 kV
Ui 250 V
Ithe 6 A
Ie/Ue 6 A/250 VAC; 0,25 A/230 VDC
Utilisation category AC-15, DC-13
Max. fuse rating 6 A gL / gG D-fuse
Positive break travel 9 mm
Positive break force -
Ambient temperature –20 °C … +60 °C
Mechanical life > 1 million operations
Ex-marking EEx geprüft II 2G EEx d IIC T6, II 2D IP67 T80°C
Approvals DMT 01 ATEX E 118

Contact variants

  Slow action   
1 NC/1 NO contact
EEx 95 AZ 1Ö/1S
2 NC contacts
EEx 95 AZ 2Ö

    Actuating radius