in series with NO contact 23-24 (internal wiring)
by internal baffle after pressure point, Safety contact: 13-14
, Signalling contact: 21-22
| Standards | EN ISO 13849-1; IEC/EN 60947-5-1, BG-GS-ET-15 |
|---|---|
| Enclosure | aluminium die-cast, enamel finish, |
| Pedal | glass-fibre reinforced thermoplastic |
| Protective shield | aluminium die-cast, enamel finish, |
| Connection | screw terminals |
| Wire cross-section | max. 2.5 mm² (incl. conductor ferrules) |
| Cable entry | M20 x 1.5 |
| Contact material | Silver |
| Degree of protection | IP 65 to IEC/EN 60529 |
| Switching system | slow action with double break, positive break NC contact per IEC 60947-5-1 |
| Switch insert | ES 60 GF VD, ES 60 GF IK VD |
| Contacts | 1 NO/1 NC or 2 NO/2 NC contacts |
| Actuating force | approx. 240 N |
| B10d (10% Load) | 200.000 |
| TM | 10 years |
| Utilisation category | AC-15 |
| Uimp | 6 kV |
| Ui | 500 V |
| Ithe | GFS VD: 16 A, GFS IK VD: 6 A |
| Ie/Ue | GFS VD: 16 A/400 VAC, GFS IK VD: 6 A/400 VAC |
| Contact load capacitiy | max. 400 VAC, GFS VD: max. 16 A (cos φ = 1), GFS IK VD: max. 6 A (cos φ = 1) |
| Max. fuse rating | GFS VD: 16 A gL/gG D-fuse, GFS IK VD: 6 A gL/gG D-fuse |
| Ambient temperature | –25 °C … +80 ºC |
| Mechanical life | > 100.000 operations |
| Approvals | GFS VD: / GFS IK VD: ![]() |

GFS 1S D 1Ö VD 81225001/ Download >
GFS IK 1Ö1S D 1Ö VD81281905/ Download >
GFS 2S D 2Ö VD 81233001/ Download >
GFS IK 2Ö2S D 2Ö VD81281904/ Download >