// CONTROL TECHNOLOGY

Command devices
ES 14

Technical data

Standards EN ISO 13849-1; IEC/EN 60947-5-1
Enclosure glass-fibre reinforced, shock-proof thermoplastic, self-extinguishing UL 94-V0
Degree of protection IP 65/67 to IEC/EN 60529
Contact material silber
Switching system slow action, positive break NC contacts Zwangsöffnung
Switching elements change-over contact with double break or 2 NC contacts, galvanically separated contact bridges
Connection cable H05VV-F
Cable section 4 x 0.75 mm²
Uimp 4 kV
Ui 250 V
Ithe 6 A
Ie/Ue 6 A/250 VAC; 0,25 A/230 VDC
Utilisation category AC-15, DC-13
Max. fuse rating 6 A gL/gG D-fuse
Ambient temperature –20 °C … +75 °C
Mechanical life > 1 million operations
Switching frequency 1800/h
Contact opening 2 x 4 mm

Ordering details

 
Push button RT
TypeOrder no.
ES 14 RT 1Ö/1S14055001/ Download >
Push button with diaphragm RTM
TypeOrder no.
ES 14 RTM 1Ö/1S14055002/ Download >
Selector RW
TypeOrder no.
ES 14 RWA 0 - I 14057001/ Download >
ES 14 RWA I - II 14057002/ Download >
ES 14 RWB I - 0 - II 14057003/ Download >
ES 14 RWC I - 0 ← II 14057005/ Download >
Control switch RST
TypeOrder no.
ES 14 RSTA 0 ← I 14057006/ Download >
ES 14 RSTB I → 0 ← II 14057007/ Download >
Key switch RSSA
TypeOrder no.
ES 14 RSSA 12 14058001/ Download >
ES 14 RSSA 1314058002/ Download >
ES 14 RSSA 1414058003/ Download >
ES 14 RSSA 1514058004/ Download >
ES 14 RSSA 1714058005/ Download >
ES 14 RSSA 1814058006/ Download >
ES 14 RSSA 2314058007/ Download >
ES 14 RSSA 2414058008/ Download >
ES 14 RSSA 2714058009/ Download >
Push button RS SW
TypeOrder no.
ES 14 RS SW 1Ö/1S14055004/ Download >
Emergency stop push button RUV
TypeOrder no.
ES 14 RUV 1Ö/1S14059001/ Download >
ES 14 RUV 2Ö14559001/ Download >