ES 50

Features/Options

  • Thermoplastic enclosure
  • Change-over contact with double break, positive break NC contact Zwangsöffnung
  • Galvanically separated contact bridges
  • Available for top mounting with 2 x M3 tapped holes

Product image

 

Technical data

Standards IEC/EN 60947-5-1
Enclosure glass-fibre reinforced, shock-proof thermoplastic, self-extinguishing UL 94-V0
Actuator plunger: brass
Degree of protection IP 30 to IEC/EN 60529
Soiling level 3
Contact material silver
Switching system slow action, positive break NC contact Zwangsöffnung
Switching elements change-over contact with double break Zb and galvanically separated contact bridges
Connection plug-in connector
Cable section max. 1.5 mm²
B10d (10% Load) 70.000
TM max. 20 years
Uimp 4 kV
Ui 400 V
Ithe 4 A
Ie/Ue 4 A/400 VAC
Utilisation category AC-15
Max. fuse rating 4 A gL/gG D-fuse
Ambient temperature –20 °C … +75 ºC
Mechanical life > 1 million operations
Switching frequency 1800/h
Repeat accuracy of switching points ± 0.1 mm
Impact resistance/ Contact opening 2 x 4 mm
Approvals